Reapplies for a Letter of Authorization (LOA) for an Express Connect circuit after a previous application was denied.
Try it now
Test
RAM authorization
Request parameters
|
Parameter |
Type |
Required |
Description |
Example |
| ClientToken |
string |
No |
The client token that ensures the idempotence of the request. You can use the client to generate the token, but make sure the token is unique among different requests. Note
If you do not specify this parameter, the system automatically uses the request ID as the client token. The request ID may be different for each request. |
123e4567-e89b-12d3-a456-426655440000 |
| RegionId |
string |
Yes |
The region of the Express Connect circuit. Call the DescribeRegions operation to query available regions. |
cn-hangzhou |
| Bandwidth |
integer |
No |
The bandwidth of the Express Connect circuit. Unit: Mbit/s. Valid values: 2 to 10240. |
3 |
| PeerLocation |
string |
No |
The geographic location of the Express Connect circuit. |
杭州 |
| InstanceId |
string |
Yes |
The ID of the Express Connect circuit. |
pc-bp1qrb3044eqi**** |
| CompanyName |
string |
Yes |
The name of the company that requires the Express Connect circuit. |
company |
| LineType |
string |
Yes |
The type of Express Connect circuit. Valid values:
|
FIBRE |
| Si |
string |
Yes |
The construction company. |
阿里 |
| ConstructionTime |
string |
Yes |
The construction start time in the ISO 8601 format (YYYY-MM-DDThh:mm:ssZ). The time is in UTC. |
2022-02-28T16:00:00Z |
| PMInfo |
array<object> |
No |
The information about the construction engineer. |
|
|
object |
No |
|||
| PMCertificateNo |
string |
No |
The ID number of the construction engineer. Valid values: ID card number or international passport number. You can specify up to 16 construction engineers. |
5****************9 |
| PMName |
string |
No |
The name of the construction engineer. |
张三 |
| PMCertificateType |
string |
No |
The type of the identity document of the construction engineer. Valid values:
|
IDCard |
| PMGender |
string |
No |
The gender of the construction engineer. |
Male |
| PMContactInfo |
string |
No |
The contact information of the construction engineer. |
1390000**** |
Response elements
|
Element |
Type |
Description |
Example |
|
object |
|||
| RequestId |
string |
The request ID. |
A47BD386-7FDE-42C4-8D22-C6223D18AA1C |
Examples
Success response
JSON format
{
"RequestId": "A47BD386-7FDE-42C4-8D22-C6223D18AA1C\t\n"
}
Error codes
|
HTTP status code |
Error code |
Error message |
Description |
|---|---|---|---|
| 400 | OperationFailed.PconnTrafficNotEnable | The operation is failed because of PconnTrafficNotEnable. | Billing for outbound data transfer is disabled. |
| 400 | IllegalParam.Bandwidth | Invalid Bandwidth. | The bandwidth of the Express Connect circuit is invalid. |
| 400 | IllegalParam.CompanyLocalizedName | Invalid CompanyLocalizedName. | The localized name of the company is invalid. |
| 400 | IllegalParam.CompanyName | Invalid CompanyName. | The company name is invalid. |
| 400 | IllegalParam.LineType | Invalid LineType. | The Express Connect circuit type is invalid. |
| 400 | IllegalParam.PeerLocation | Invalid PeerLocation. | The location of the Express Connect circuit is invalid. |
| 400 | IllegalParam.PmCertificateType | Invalid PmCertificateType. | The certificate type of the engineer is invalid. |
| 400 | IllegalParam.PmCertificateNo | Invalid PmCertificateNo. | The certificate number of the engineer is invalid. |
| 400 | IllegalParam.PmContactInfo | Invalid PmContactInfo. | The contact information about the engineer is invalid. |
| 400 | IllegalParam.PmGender | Invalid PmGender. | The engineer gender is invalid. |
| 400 | IllegalParam.PmName | Invalid PmName. | The engineer name is invalid. |
| 400 | IllegalParam.Si | Invalid Si. | The construction company is invalid. |
| 400 | InvalidInstanceId.NotFound | InstanceId is not found. | The Express Connect circuit ID is invalid. |
| 400 | IncorrectStatus.PhysicalConnection | Invalid physical connection status. | The Express Connect circuit is in an invalid state. |
| 400 | IncorrectStatus.PhysicalConnectionLOA | Invalid Express Connect circuit LOA status. | The construction status of the Express Connect circuit is invalid. |
| 400 | OperationDenied.LOAForVirtualPhysicalConnection | The operation is not allowed because of LOAForVirtualPhysicalConnection. | The shared Express Connect circuit does not allow construction. |
| 400 | MissingParam.InstanceId | The parameter InstanceId is mandatory. | You must specify the Express Connect circuit ID. |
| 400 | MissingParam.ConstructionTime | The parameter ConstructionTime is mandatory. | You must specify the start time. |
| 400 | MissingParam.PMInfo | The parameter PMInfo is mandatory. | You must specify the engineer information. |
See Error Codes for a complete list.
Release notes