Creates Express Connect circuits in zone-redundancy mode to ensure the stability of multi-line access to your workloads on Alibaba Cloud and to avoid service disruptions caused by single-line failures through multi-line disaster recovery.
Operation description
When you purchase ports, you can select one of the following three combination types to provide disaster recovery capabilities for your workloads.
-
Maximum disaster recovery: You apply for resources in two access points and establish four independent Express Connect circuit connections. The SLA availability for maximum disaster recovery is no less than 99.99%.
-
Enhanced disaster recovery: You apply for resources in two access points and establish two independent Express Connect circuit connections. The SLA availability for enhanced disaster recovery is no less than 99.95%.
-
Development and testing: You apply for resources in one access point and establish two independent Express Connect circuit connections.
Try it now
Test
RAM authorization
|
Action |
Access level |
Resource type |
Condition key |
Dependent action |
|
vpc:CreateHighReliablePhysicalConnection |
create |
*All Resource
|
None | None |
Request parameters
|
Parameter |
Type |
Required |
Description |
Example |
| RegionId |
string |
No |
The region ID of the Express Connect circuit. You can call the DescribeRegions operation to query the region ID. |
cn-shanghai |
| ClientToken |
string |
No |
The client token that is used to ensure the idempotence of the request. You can use the client to generate the token, but you must make sure that the token is unique among different requests. The client token can contain only ASCII characters. Note
If you do not specify this parameter, the system automatically uses the RequestId of the API request as the ClientToken. The RequestId may be different for each API request. |
123e4567-e89b-12d3-a456-426655440000 |
| ClientToken |
string |
No |
客户端 Token,用于保证请求的幂等性。 从您的客户端生成一个参数值,确保不同请求间该参数值唯一。ClientToken 只支持 ASCII 字符。 Note
若您未指定,则系统自动使用 API 请求的 RequestId 作为 ClientToken 标识。每次 API 请求的 RequestId 不一样。 |
123e4567-e89b-12d3-a456-426655440000 |
| ResourceGroupId |
string |
No |
The ID of the resource group to which the Express Connect circuit belongs. |
rg-acfmxazb4p**** |
| Tag |
array<object> |
No |
The tags. |
|
|
object |
No |
The tags. |
||
| Key |
string |
No |
The tag key of the resource. You can specify up to 20 tag keys. The tag key cannot be an empty string. The tag key can be up to 64 characters in length and must start with a letter or Chinese character. It can contain digits, periods (.), underscores (_), and hyphens (-). It cannot start with |
FinanceDept |
| Value |
string |
No |
The tag value of the resource. You can specify up to 20 tag values. The tag value can be an empty string. The tag value can be up to 128 characters in length and must start with a letter or Chinese character. It can contain digits, periods (.), underscores (_), and hyphens (-). It cannot start with |
FinanceJoshua |
| HighReliableType |
string |
Yes |
The zone-redundancy mode. Valid values:
|
MultiApMultiDevice |
| PortType |
string |
Yes |
The port type of the Express Connect circuit. Valid values:
Note
40GBase-LR and 100GBase-LR are subject to the actual port availability. For information about port availability, contact your account manager. |
1000Base-LX |
| DeviceAdvancedCapacity |
array |
No |
The list of advanced device capabilities. |
|
|
string |
No |
The advanced device capability. Valid values:
|
SubifRateLimit |
|
| ApList |
array<object> |
Yes |
The list of access points. |
|
|
object |
No |
The list of access points. |
||
| Name |
string |
No |
The name of the Express Connect circuit. The name must be 2 to 128 characters in length and must start with a letter or Chinese character. It can contain digits, underscores (_), and hyphens (-), but cannot start with |
test |
| Description |
string |
No |
The description of the Express Connect circuit. The description must be 2 to 256 characters in length and must start with a letter or Chinese character, but cannot start with |
description |
| RegionId |
string |
Yes |
The region ID of the Express Connect circuit. You can call the DescribeRegions operation to query the region ID. |
cn-shanghai |
| LineOperator |
string |
Yes |
The connectivity provider of the Express Connect circuit. Valid values:
|
CT |
| AccessPointId |
string |
Yes |
The ID of the access point for the Express Connect circuit. Note
When HighReliableType is set to MultiApMultiDevice or MultiApSingleDevice, you must specify two different access points. When HighReliableType is set to SingleApMultiDevice or SingleApMultiConnection, you must specify one access point. |
ap-cn-beijing-ft-A |
| PortNum |
integer |
No |
The number of ports. This parameter is required only when HighReliableType is set to SingleApMultiConnection. Valid values: 2 to 16. |
2 |
| Type |
string |
No |
The type of the Express Connect circuit. Default value: VPC. |
VPC |
| Bandwidth |
integer |
No |
The bandwidth of the shared Express Connect circuits. Unit: Mbit/s. Valid values: 50, 100, 200, 300, 400, 500, 1000, 2000, 4000, 5000, 8000, and 10000. |
50 |
| PeerLocation |
string |
No |
The geographic location of the on-premises data center. |
XX街道 |
| CircuitCode |
string |
No |
The circuit code provided by the connectivity provider for the Express Connect circuit. |
longtel001 |
| OpticalModuleModel |
string |
No |
The optical module model supported by the access point of the Express Connect circuit. Valid values:
|
SFP-GE-LR-SM1310,10KM |
| DryRun |
string |
No |
Specifies whether to perform a dry run. Valid values:
|
false |
| AcceptLanguage |
string |
No |
The language of the response. Valid values:
|
zh-CN |
Response elements
|
Element |
Type |
Description |
Example |
|
object |
The response parameters. |
||
| PhysicalConnectionList |
object |
||
| physicalConnectionList |
array<object> |
The list of Express Connect circuit instances. |
|
|
object |
The list of Express Connect circuit instances. |
||
| InstanceId |
string |
The ID of the Express Connect circuit. |
pc-j5e5qqo616p81ncsp**** |
| RegionNo |
string |
The region ID of the Express Connect circuit. |
cn-shanghai |
| RequestId |
string |
The request ID. |
0ED8D006-F706-4D23-88ED-E11ED28DCAC0 |
| ErrorInfoList |
object |
||
| errorInfoList |
array<object> |
The error codes and error messages returned when the dry run fails. All error information is returned, including:
|
|
|
object |
The error code. |
||
| ErrorCode |
string |
Error codes. |
pconn.high.reliable.dryrun.error.disable.outbound.data.transfer.billing |
| ErrorMessage |
string |
The returned error message. |
pconn.high.reliable.dryrun.error.disable.outbound.data.transfer.billing |
| InstanceId |
string |
The ID of the Express Connect circuit. |
pc-j5e5qqo616p81ncsp**** |
Examples
Success response
JSON format
{
"PhysicalConnectionList": {
"physicalConnectionList": [
{
"InstanceId": "pc-j5e5qqo616p81ncsp****",
"RegionNo": "cn-shanghai"
}
]
},
"RequestId": "0ED8D006-F706-4D23-88ED-E11ED28DCAC0",
"ErrorInfoList": {
"errorInfoList": [
{
"ErrorCode": "pconn.high.reliable.dryrun.error.disable.outbound.data.transfer.billing",
"ErrorMessage": "pconn.high.reliable.dryrun.error.disable.outbound.data.transfer.billing",
"InstanceId": "pc-j5e5qqo616p81ncsp****"
}
]
}
}
Error codes
|
HTTP status code |
Error code |
Error message |
Description |
|---|---|---|---|
| 400 | Invalid.Status | The device or interface status invalid, or has been used.. | The Status parameter is set to an invalid value. |
| 400 | InvalidType.Malformd | The Type provided was invalid. | |
| 400 | InvalidPeerLocation.Malformd | The PeerLocation provided was invalid. | |
| 400 | InvalidLineOperator.Malformd | The LineOperator provided was invalid. | |
| 400 | InvalidPortType.Malformd | The PortType provided was invalid. | |
| 400 | InvalidDescription.Malformed | The specifid ?Description? is not valid. | The error message returned because the specified resource description is invalid. The description must be 2 to 256 characters in length and cannot start with http:// or https://. |
| 400 | InvalidRedundantPhysicalConnectionId.NotFound | The RedundantPhysicalConnectionId does not found. | |
| 400 | InvalidName.Malformed | The specified ?Name? is not valid. | |
| 400 | QuotaExceeded.pConnPerAP | Physical connection count per ap quota exceed. | |
| 400 | InvalidBandwidth | invalid physical connection banwidth. | |
| 400 | InvalidRedundantPhysicalConnection | redundant physical connection doesn't belong to current user. | |
| 400 | InvalidRedundantPhysicalConnectionStatus | invalid redundant physical connection status. | |
| 400 | InvalidCircuitCode.Malformed | circuitCode is illegal. | |
| 400 | QuotaExceeded.freePconnPerAP | free physical connections count excceeded. | |
| 400 | InvalidPhysicalConnectionOperator.Malformed | Specified PhysicalConnection Operator is not valid. | The operation on the Express Connect circuit is invalid. |
| 400 | InvalidPhysicalConnectionPortType.Malformed | Specified PhysicalConnection PortType is not valid. | The port type of the Express Connect circuit is invalid. |
| 400 | InvalidPhysicalConnectionBandwidth.Malformed | Specified PhysicalConnection Bandwidth is not valid. | The bandwidth of the Express Connect circuit is set to an invalid value. |
| 400 | IllegalParam.ClientToken | Token verify failed because client token length too long. | The ClientToken parameter is set to an invalid value. |
| 400 | InvalidPortType.NotFound | Specified port type is not found. | The portType parameter is not set. |
| 400 | OperationFailed.PconnTrafficNotEnable | The operation is failed because of PconnTrafficNotEnable. | Billing for outbound data transfer is disabled. |
| 400 | EcNotSupportRegion | High reliable physical connection is not support in this region. | Highly reliable physical lines are temporarily not supported for sale in the local region. |
| 400 | EcFailToGetAp | Fail to get access point details. | Unable to query the corresponding access point information. |
| 400 | EcNotEnoughResource | Insufficient access point resources. | Insufficient Access Point Resources |
| 400 | IllegalParam.UnsupportedAccessPoint | The access point type does not support the creation of a highly reliable physical connection. | You cannot create a high-availability Express Connect circuit for an access point of this type. |
| 400 | ResourceNotFound.AccessPointId | The specified resource of access point id is not found. | The current access point information does not exist. Please check and try again. |
| 400 | IllegalParam.%s | The param of %s is illegal. | The parameter is invalid. |
| 404 | InvalidPortType.NotFound | There are no resources with the portType. | The specified port type is invalid. |
See Error Codes for a complete list.
Release notes