Attaches a virtual private cloud (VPC) to a transit router. Once connected, the transit router enables private network communication.
Operation description
You can create a VPC connection for an Enterprise Edition transit router in one of two ways:
If you have an Enterprise Edition transit router in the target region, you can create a VPC connection by specifying VpcId, ZoneMappings.N.VSwitchId, ZoneMappings.N.ZoneId, TransitRouterId, and RegionId.
If you do not have an Enterprise Edition transit router in the target region, you can create a VPC connection by specifying VpcId, ZoneMappings.N.VSwitchId, ZoneMappings.N.ZoneId, CenId, and RegionId. When you create the VPC connection, the system automatically creates an Enterprise Edition transit router.
CreateTransitRouterVpcAttachment is an asynchronous operation. After you send a request, the system returns a VPC connection ID, and the connection is created in the background. Call the ListTransitRouterVpcAttachments operation to query the status of the VPC connection.
The Attaching state indicates that the VPC connection is being created. In this state, you can only query the VPC connection.
The Attached state indicates that the VPC connection has been created.
By default, a newly created VPC connection is not associated with any transit router route table for route learning or forwarding.
Prerequisites
Before you call this API operation to create a VPC connection, ensure the following prerequisites are met:
The VPC must have at least one vSwitch in a zone that supports Enterprise Edition transit routers. The vSwitch must have at least one available IP address. For more information about supported regions and zones, see Regions and zones that support Enterprise Edition transit routers.
To connect a cross-account network instance, you must first have the required permissions. For more information, see Grant permissions on a network instance that belongs to another account.
Creating a VPC connection incurs costs. Ensure you understand the billing rules. For more information, see Billing.
Try it now
Test
RAM authorization
Action | Access level | Resource type | Condition key | Dependent action |
cen:CreateTransitRouterVpcAttachment | create | CenInstance
TransitRouter
| None | None |
Request parameters
Parameter | Type | Required | Description | Example |
ClientToken | string | No | The client token used to ensure request idempotency. You must generate a value on your client that is unique among different requests. The token can contain only ASCII characters. Note If you do not specify this parameter, the system automatically uses the request ID as the client token, which is unique for each request. | 02fb3da4-130e-11e9-8e44-001**** |
CenId | string | No | The ID of the CEN instance. | cen-j3jzhw1zpau2km**** |
TransitRouterId | string | No | The ID of the Enterprise Edition transit router. | tr-bp1su1ytdxtataupl**** |
RegionId | string | No | The ID of the region where the VPC is located. You can call the DescribeChildInstanceRegions operation to query region IDs. | cn-hangzhou |
TransitRouterAttachmentName | string | No | The name of the VPC connection. The name can be empty or 1 to 128 characters long, and cannot start with | testname |
TransitRouterAttachmentDescription | string | No | The description of the VPC connection. The description can be empty or 1 to 256 characters long, and cannot start with | testname |
VpcId | string | Yes | The ID of the VPC. | vpc-bp1kbjcre9vtsebo1**** |
VpcOwnerId | integer | No | The ID of the Alibaba Cloud account that owns the VPC. By default, this is the ID of the current Alibaba Cloud account. Note This parameter is required if you want to attach a cross-account network instance. | 1250123456123456 |
ChargeType | string | No | The billing method. The default value is POSTPAY (pay-as-you-go). | POSTPAY |
DryRun | boolean | No | Specifies whether to perform a dry run to check the validity of the request without creating the resource. The check includes permissions and instance status. Valid values:
| false |
| ZoneMappings | array<object> | Yes | The zone mappings for the VPC connection. For each mapping, you must specify a vSwitch in a zone that is supported by the Enterprise Edition transit router. You can specify up to 10 zone mappings. | |
object | No | A mapping between a vSwitch and a zone. | ||
VSwitchId | string | Yes | The ID of the vSwitch. | vsw-bp1a214sbus8z3b54**** |
ZoneId | string | Yes | The ID of the zone. The zone must be supported by the Enterprise Edition transit router. You can call the DescribeZones operation to query available zones. | cn-hangzhou-h |
AutoPublishRouteEnabled | boolean | No | Specifies whether to enable the Enterprise Edition transit router to automatically advertise routes to the VPC.
| true |
| TransitRouterVPCAttachmentOptions | object | No | The properties of the VPC connection. This parameter is deprecated. We recommend that you use the | |
string | No | The properties of the VPC connection. This parameter is deprecated. We recommend that you use the ipv6Support: Specifies whether to enable IPv6. Valid values:
Note Before you enable IPv6 for the VPC connection, make sure that IPv6 is also enabled for the VPC and its associated vSwitches. For more information, see AllocateVpcIpv6Cidr and CreateVSwitchCidrReservation. | disable | |
| Tag | array<object> | No | The tags to add to the VPC connection. You can add up to 20 tags. | |
object | No | The key and value of the tag. | ||
Key | string | No | The key of the tag. The tag key cannot be an empty string. The key can be up to 64 characters long and cannot start with | tagtest |
Value | string | No | The value of the tag. The tag value can be an empty string or a string up to 128 characters long. It cannot start with | tagtest |
Response elements
Element | Type | Description | Example |
object | The response data. | ||
TransitRouterAttachmentId | string | The ID of the VPC connection. | tr-attach-ia340z7xis7t5s**** |
RequestId | string | The request ID. | C087A369-82B9-43EF-91F4-4B63A9C6E6B6 |
Examples
Success response
JSON format
{
"TransitRouterAttachmentId": "tr-attach-ia340z7xis7t5s****",
"RequestId": "C087A369-82B9-43EF-91F4-4B63A9C6E6B6"
}Error codes
HTTP status code | Error code | Error message | Description |
400 | OperationUnsupported.TransitRouterRegionId | The specified TransitRouterRegion does not support the operation. | |
400 | NoPermission.AliyunServiceRoleForCEN | You are not authorized to create the service linked role. Role Name: AliyunServiceRoleForCEN. Service Name: cen.aliyuncs.com. Make sure that the user has been granted the ram:CreateServiceLinkedRole permission. | The error message because you do not have the permissions to create the service-linked role whose role name is AliyunServiceRoleForCEN and service name is cen.aliyuncs.com. You must acquire the ram:CreateServiceLinkedRole permission before you can create the service-linked role. |
400 | IllegalParam.RegionId | The Specified Parameter RegionId is illegal | The error message returned because the specified region is invalid. |
400 | MissingParam.CenIdOrRegionId | Either CenId or RegionId must be specified. | The error message returned because the CenId or RegionId parameter is not set. |
400 | IllegalParam.ZoneId | The specified ZoneId is illegal. | The error message returned because the specified zone is invalid. |
400 | IllegalParam.ChargeType | The specified ChargeType is illegal. | The error message returned because the specified billing method is invalid. |
400 | InvalidTransitRouterId.NotFound | The specified TransitRouterId is not found. | The error message returned because the specified transit router does not exist. |
400 | IncorrectStatus.VpcResource | The resource is not in a valid state for the attachment operation. | The error message returned because this operation is not supported when the specified VPC is in an unstable state. Wait until all operations related to the VPC are completed. |
400 | IncorrectStatus.Vpc | The resource is not in a valid state for the attachment operation. | The error message returned because the status of the VPC does not support this operation. Try again later. |
400 | IncorrectStatus.VpcOrVswitch | The Vpc Or Vswith is not in a valid state for the attachment operation. | The error message returned because the status of the VPC or vSwitch does not support this operation. Try again later. |
400 | OperationNotSupport.VpcAutoRoutesPublish | Auto publish vpc routes is not supported in this region. | The error message returned because automatic route advertising for VPCs is not supported in the specified region. |
400 | InvalidOperation.VpnAssociated | The operation is not supported because the VPC is associated with VPN. | The error message returned because the specified VPC is associated with a VPN. |
400 | Forbbiden.TransitRouterServiceNotOpen | The user has not open transit router service. | The error message returned because the transit router is disabled. Enable the transit router and try again. |
400 | IllegalParam.ZoneMappings | The Specified Parameter ZoneMappings is illegal | The error message returned because the specified zone mappings (ZoneMappings) is invalid. |
400 | OperationUnsupported.TransitRouterType | The specified TransitRouterType does not support the operation. | The error message returned because this operation is not supported by the specified type of transit router. |
400 | InvalidCenId.NotFound | CenId is not found. | The error message returned because the specified CEN instance does not exist. |
400 | IllegalParam.VSwitchId | VSwitchId is illegal. | The error message returned because the specified vSwitch ID is invalid. |
400 | IncorrectStatus.TransitRouterInstance | The status of TransitRouter is incorrect. | The error message returned because the transit router is in an invalid state. |
400 | OperationUnsupported.CenFullLevel | CEN full level does not support TransitRouter | The error message returned because CEN instances of the Full type do not support Enterprise Edition transit routers. |
400 | IllegalParam.ServiceMode | ServiceMode is illegal. | The error message returned because the specified service mode is invalid. |
400 | QuotaFull.ChildInstanceRelatedCen | The childinstance has exceed the quota of the times that a childinstance can be attached as an attachment. | The error message returned because the number of CEN instances to which the instance is attached has reached the upper limit. You cannot attach the instance to more CEN instances. |
400 | OperationUnsupported.CloudBoxVswNotSupport | Cloud Box vsw does not support. | The error message returned because the instance cannot be connected to the CloudBox vSwitch. |
400 | IncorrectStatus.TransitRouter | The status of TransitRouter is incorrect. | The error message returned because the status of the transit router does not support this operation. Try again later. |
400 | Duplicated.ZoneMapping | The parameter ZoneMapping is duplicated. | The error message returned because the zone mapping contains duplicate routes. |
400 | QuotaExceeded.CenQuotaVpcAttachPerTransitRouter | The maximum number of VPC attachment per Transit Router is exceeded. | The error message returned because the specified number of VPCs to be attache to the transit router exceeds the upper limit. |
400 | IncorrectStatus.VpcRouteTable | The VPC route table is not in a desired state. | The error message returned because the VPC route table is in an unstable state. Try again later. |
400 | InvalidStatus.VpcAttachedFullModeCen | The VPC has been attached to another CEN instance whose protection level is FULL. | The error message returned because the specified VPC is already attached to a CEN instance whose protection level is FULL. The VPC cannot be attached to other CEN instances. |
400 | Forbbiden.AttachChildInstanceAcrossBid | VPCs that belong to another BID cannot be associated. You need to apply for cross-BID attaching. | The error message returned because you cannot associate with VPCs that belong to another BID. |
400 | InvalidOperation.VpcAutoRoutesPublishInOtherCEN | The specified VPC already has its routes synchronized with another CEN instance. | The error message returned because this operation is not supported when route synchronization is enabled between the current VPC and another CEN instance. |
400 | QuotaExceeded.VpcAutoRoutesPublishPerTransitRouter | The number of VPCs that have route synchronization enabled has reached the upper limit. | The error message returned because the number of VPCs that have route synchronization enabled has reached the upper limit. |
400 | InsufficientIpAddr.vsw | Insufficient available IP addresses in the vSwitch. | The error message returned because the number of available IP addresses in the vSwitch is insufficient. |
400 | Forbidden.ResourceOwnerTransitRouterServiceNotOpen | The resource owner user has not opened transit router service. | The transit router service for the resource owner's account is not currently opened. Please inform them to open the transit router service and then try again. |
400 | IllegalParam.TransitRouterRegionId | TransitRouterRegionId is illegal. | The error message returned because the specified transit router region ID (TransitRouterRegionId) is invalid. |
400 | InvalidTransitRouterMode.NeedUpgrade | TransitRouter need to upgrade. | The error message returned because the specified transit router mode is not supported. |
400 | IllegalParam.Ipv6Support | Ipv6Support is illegal. Valid Values are [enable, disable]. | The Ipv6Support value of the request parameter is invalid. The valid value is enable or disable. |
400 | OperationFailed.VSwitchNotFound | The specified vswitch not found. | The specified vswitch not found. |
400 | OperationFailed.VSwitchIpv6CidrNotAllocated | The specified vswitch does not have IPv6 address allocated. | The specified vswitch does not have IPv6 address allocated. |
400 | Forbidden.ResourceOwnerTransitRouterServiceExpired | The transit router service of the account to which the resource belongs has been suspended due to arrears. Please notify the other party to renew the service and try again. | The transit router service of the account to which the resource belongs has been suspended. Please notify the other party to renew the service and try again. |
400 | Forbidden.TransitRouterServiceExpired | The transit router service is out of service. | The transit router service has been suspended due for payment. Please renew the service and try again. |
400 | InvalidParameter | Invalid parameter. | The error message returned because the parameter is set to an invalid value. |
400 | Unauthorized | The AccessKeyId is unauthorized. | The error message returned because you do not have the permissions to perform this operation. |
400 | InvalidParameter.ResourceType | The specified parameter ResourceType is invalid. | |
400 | ParamExclusive.TransitRouterVPCAttachmentOptionsAndOptions | When creating or modifying a VPC attachment, the input parameter TransitRouterVPCAttachmentOptions and Options cannot be used at the same time. | When creating or modifying a VPC attachment, the input parameter TransitRouterVPCAttachmentOptions and Options cannot be used at the same time. |
400 | InvalidParameter.ApplianceModeSupport | The specified parameter ApplianceModeSupport is invalid. | The parameter ApplianceModeSupport entered is illegal. |
400 | InvalidParameter.Ipv6Support | The specified parameter Ipv6Support is invalid. | The parameter Ipv6Support entered is illegal. |
400 | INVALID_OPERATION_RESOURCE_NOT_SUPPORT_APPLIANCE_MODE | Only VPC attachment support appliance mode. | Only VPC attachment support appliance mode. |
404 | InvalidVSwitchId.NotFound | The specified VSwitchId is not found. | The error message returned because the specified vSwitch ID does not exist. |
409 | InvalidOperation.CenInstanceStatus | The CEN instance is not in a valid state for the operation. | The error message returned because the status of the CEN instance does not support this operation. |
409 | IncorrectStatus.VpcSwitch | The resource is not in a valid state for the attachment operation. |
See Error Codes for a complete list.
Release notes
See Release Notes for a complete list.