This topic describes the limits of Express Connect that you must take note of before you get started.
Limits on resources
For more information, see Express Connect quotas.
Limits on networks
To connect a data center to Alibaba Cloud over an Express Connect circuit, make sure that the CIDR blocks of services on Alibaba Cloud and the CIDR blocks of the data center do not conflict with each other. In addition, make sure that the data center meets the following requirements:
If you use optical fiber cables, you must use one of the following types of single-mode optical transceiver modules to connect to the access device of Alibaba Cloud. The configurations of the optical transceiver modules must be the same on both ends of the connection.
1000 Base-LX single-mode optical transceiver module
10 GBase-LR single-mode optical transceiver module
40 GBase-LR single-mode optical transceiver module
100 GBase-LR single-mode optical transceiver module
You must disable auto-negotiation for the port. Then, specify the port rate and set the duplex mode to full-duplex.
All devices used to establish the connection support 802.1Q virtual local area network (VLAN) encapsulation, including the intermediary devices in data centers.
The gateway device in your data center must support Border Gateway Protocol (BGP) and BGP MD5 authentication or static routing.
To use a redundant Express Connect circuit, you must set route weights on your gateway device.
The maximum transmission unit (MTU) on the physical layer is 1,500 bytes.
We recommend that you use private IP addresses to establish the connection between your data center and Alibaba Cloud. In addition, the CIDR blocks specified for the connection cannot conflict with each other.
You cannot set the CIDR block of the data center to 100.64.0.0/10 in case it conflicts with the CIDR blocks of the services in Alibaba Cloud.
You cannot specify 100.64.0.0/10 as the peer CIDR block for the virtual border router (VBR) in Alibaba Cloud or the gateway device in the data center.
The gateway device in the data center must be able to receive more than 500 Internet Control Message Protocol (ICMP) echo requests per second. Otherwise, the gateway device cannot promptly respond to probe packets sent for health checks and consequently network jitter occurs.
Limits on transmission rates (Alibaba Cloud side)
Data transmission between a virtual private cloud (VPC) and a data center is throttled when you use an Express Connect circuit. In addition, the communication between a VPC and a data center is throttled due to the following reasons:
The maximum read/write speed for Object Storage Service (OSS) is 10 Gbit/s.
To improve reliability, the following rules apply to the maximum bandwidth of an individual hashed traffic flow from a VPC to a VBR:
If the VBR or VPC-to-VBR bandwidth ≤ 1 Gbit/s, the maximum bandwidth is the specified bandwidth.
If the VBR or VPC-to-VBR bandwidth > 1 Gbit/s, the maximum bandwidth is 1/4 of the specified bandwidth. For example, if the VPC-to-VBR bandwidth is 2 Gbit/s, the maximum bandwidth is 500 Mbit/s.
NoteIf a data center is connected to the cloud by using CEN or ECR, traffic is throttled based on the VBR bandwidth. If the data center is connected to the cloud through VBR-to-VPC connections, traffic is throttled based on the VBR-to-VPC bandwidth.
You cannot use VBR-to-VPC connections by default. To use this feature, contact your account manager.
A hashed traffic flow is a data stream that is defined by the combination of the source IP address, source port, transport layer protocol, destination IP address, and destination port. For example,
192.168.1.1 10000 TCP 121.XX.XX.76 80forms a hashed traffic flow. In this traffic flow, a terminal that is assigned with the IP address 192.168.1.1 and port 10000 is connected to a terminal that is assigned with the IP address 121.XX.XX.76 and port 80 over TCP.
Limits on Express Connect circuits
Before you use Express Connect, you must plan the CIDR blocks of the VPC and the data center that you want to connect. Make sure that the CIDR blocks of the VPC and the data center do not overlap with each other.
Cloud services deployed in VPCs use the 100.64.0.0/10 CIDR block. Therefore, data centers that are connected to VPCs over Express Connect circuits cannot use the 100.64.0.0/10 CIDR block.
Alibaba Cloud provides single-mode optical transceiver modules of the following specifications: 1 Gbit/s, 10 Gbit/s, 40 Gbit/s, and 100 Gbit/s. These optical transceiver modules support a maximum transmission distance of 10 kilometers.
Express Connect circuits do not support virtual extensible local area network (VXLAN) traffic from the destination port 4789 over the UDP protocol.
Limits on redundant Express Connect circuits
Alibaba Cloud guarantees service availability for connections over Express Connect circuits only when the Express Connect circuits are connected to different access points. If multiple Express Connect circuits share the same access point or only one Express Connect circuit is used, service availability is not guaranteed.
If a data center is connected to a VPC over two Express Connect circuits, you must specify source IP addresses and destination IP addresses for health checks. After you configure health checks for the Express Connect circuits, the system checks the status of both Express Connect circuits. If one of the Express Connect circuits is down, network traffic is transmitted over the other Express Connect circuit. We recommend that you configure health checks to detect service interruptions. This way, the system can perform failovers at the earliest opportunity.
Limits on hosted connections over Express Connect circuits
Alibaba Cloud cannot change the port settings to meet your business requirements.
When you set a bandwidth limit on a hosted connection over an Express Connect circuit, make sure that the sum of the bandwidth limits of all hosted connections does not exceed the bandwidth limit of the Express Connect circuit.
Limits on Express Connect circuit installation
The company in charge of the installation of an Express Connect circuit must follow the construction rules stipulated by connectivity providers and engineers of the Alibaba Cloud data center. Installation is forbidden in case of violation.
If you purchase optical ports, make sure that the connectivity provider uses optical fiber cables to connect to the port of Alibaba Cloud.
Alibaba Cloud data centers do not support fiber-optic transceivers. The company in charge of the installation cannot install fiber-optic transceivers in data centers of Alibaba Cloud.
The installation schedule is subject to data center lockdowns required by local authorities and Alibaba Cloud. If the data center is locked down, you can contact your account manager.
Data centers where Alibaba Cloud access points are located belong to the connectivity provider or third-party service provider. Therefore, you may be charged by a service provider for installing the Express Connect circuit in their buildings and using the indoor cables.
Time spans for Express Connect circuit installation
The following table describes the amount of time required for installing Express Connect circuits.
Work item | Duration |
Review of the application to enter an Alibaba Cloud data center and perform site surveys for the installation | Two business days |
Review of the application for a Letter of Authorization (LOA) | Two business days |
Fiber pigtail installation | The pigtail installation duration:
|
Review of the application to enter an Alibaba Cloud data center to maintain an Express Connect circuit | Three business days |