Updates a failover test job for Express Connect.
Operation description
Only failover test jobs in the Pending state can be updated.
Try it now
Test
RAM authorization
|
Action |
Access level |
Resource type |
Condition key |
Dependent action |
|
vpc:UpdateFailoverTestJob |
update |
*PhysicalConnection
*VirtualBorderRouter
|
None | None |
Request parameters
|
Parameter |
Type |
Required |
Description |
Example |
| RegionId |
string |
No |
The region ID of the failover test job. You can call DescribeRegions to query the region ID. |
cn-hangzhou |
| ClientToken |
string |
No |
The client token that is used to ensure the idempotence of the request. You can use the client to generate the token, but you must make sure that the token is unique among different requests. The client token can contain only ASCII characters. Note
If you do not specify this parameter, the system automatically uses the RequestId value as the ClientToken value. The RequestId value of each API request is different. |
123e4567-e89b-12d3-a456-426655440000 |
| ClientToken |
string |
No |
The name of the failover test job. The name must be 0 to 128 characters in length and cannot start with |
123e4567-e89b-12d3-a456-426655440000 |
| Name |
string |
No |
The description of the failover test job. The description must be 0 to 256 characters in length and cannot start with |
test |
| Description |
string |
No |
The list of failover test resource IDs. You can add up to 16 resources. |
test |
| ResourceId |
array |
No |
The duration of the failover test job. Unit: minutes. Valid values: 1 to 4320. |
|
|
string |
No |
The ID of the resource. |
pc-uf66k4e8pq3r00jfq**** |
|
| JobDuration |
integer |
No |
The failover test job ID. |
60 |
| JobId |
string |
Yes |
Specifies whether to perform a dry run. Valid values:
|
ftj-bp1yh6mvi13aq3g8w**** |
| DryRun |
boolean |
No |
Specifies whether to perform only a dry run, without performing the actual request. Valid values:
|
false |
Response elements
|
Element |
Type |
Description |
Example |
|
object |
The response parameters. |
||
| RequestId |
string |
The request ID. |
C44F62BE-9CE7-4277-B117-69243F3988BF |
Examples
Success response
JSON format
{
"RequestId": "C44F62BE-9CE7-4277-B117-69243F3988BF\n"
}
Error codes
|
HTTP status code |
Error code |
Error message |
Description |
|---|---|---|---|
| 400 | IllegalParam.Name | The param of Name [%s] is illegal. | The error message returned because the Name parameter is set to an invalid value. Specify a valid value and try again. |
| 400 | IllegalParam.Description | The param of Description [%s] is illegal. | The error message returned because the Description parameter is set to an invalid value. Specify a valid values and try again. |
| 400 | EcFailoverTestJobExceedMaxResourceNum | The input resource number is exceeded the quota of 16. | The failover test job can add up to 16 resources. |
| 400 | EcFailoverTestJobResourceInAnotherProcessingJob | There is another processing failover test job. | The current user already has a failover test job in progress. Please complete it and try again. |
| 400 | IllegalParam.ResourceId | The input parameter resource ID is invalid. | The input parameter resource ID is invalid. |
| 400 | IncorrectStatus.ResourceId | The specified resource status is invalid. | The resource status corresponding to the entered resource ID is invalid. |
| 400 | IncorrectBusinessStatus.ResourceId | The specified resource business status is invalid. | The entered resource is in arrears. |
| 400 | VpconnNotAssociatedVbr | The specified vpconn is not associated with vbr. | The entered virtual physical connection is not associated with a virtual border router. |
| 400 | VpconnWithVlan0NotSupportShutdown | The specified virtualPhysicalConnection with vlan 0 does not support shutdown. | The shared physical connection of VLAN 0 does not support failover test. |
| 400 | PconnContainsMoreThanOneVpconn | The specified physicalConnection contains more than one virtualPhysicalConnection. | A physical line that contains more than one shared physical line does not support failover test. |
| 400 | PconnContailsMoreThanOneAcrossCountVbr | The specified physicalConnection contains more than one virtualBorderRouter which is across count. | Physical connections that contain more than one cross-account VBR do not support failover test. |
| 400 | IllegalParam.JobDuration | The specified parameter JobDuration is illegal. | The task duration entered is illegal. |
| 400 | IllegalParam.JobId | The specified parameter JobId is illegal. | The entered failover test job ID is invalid. |
| 400 | IncorrectStatus.OnlyForInit | Only the init status failover test job can be started. | Only the fault drill task to be drilled can be modified or started. |
| 400 | MultiplePconnSingleVbrNotSupportShutdown | Vbr for single vbr and multiple pconn scenarios does not support failover test job. | The vbr of a single vbr and multiple pconn scenarios does not support failover test job. |
| 400 | EcFailoverTestJobConflict | The current failover test job task is in operation, please try again later. | The current failover test job task is in operation, please try again later. |
See Error Codes for a complete list.
Release notes
See Release Notes for a complete list.