Calls the StartFailoverTestJob operation to start an Express Connect failover test job.
Operation description
Only failover test jobs in the Pending state can be started.
Try it now
Test
RAM authorization
|
Action |
Access level |
Resource type |
Condition key |
Dependent action |
|
vpc:StartFailoverTestJob |
update |
*VirtualBorderRouter
*PhysicalConnection
|
None | None |
Request parameters
|
Parameter |
Type |
Required |
Description |
Example |
| RegionId |
string |
No |
The region ID of the failover test job. You can call the DescribeRegions operation to query region IDs. |
cn-hangzhou |
| ClientToken |
string |
No |
The client token that is used to ensure the idempotence of the request. You can use the client to generate the token, but you must make sure that the token is unique among different requests. The ClientToken value can contain only ASCII characters. Note
If you do not specify this parameter, the system automatically uses the RequestId of the API request as the ClientToken. The RequestId may be different for each API request. |
123e4567-e89b-12d3-a456-426655440000 |
| ClientToken |
string |
No |
The ID of the failover test job. |
123e4567-e89b-12d3-a456-426655440000 |
| JobId |
string |
Yes |
The ID of the failover test job. |
ftj-bp1yh6mvi13aq3g8w**** |
Response elements
|
Element |
Type |
Description |
Example |
|
object |
The response parameters. |
||
| RequestId |
string |
The request ID. |
C44F62BE-9CE7-4277-B117-69243F3988BF |
Examples
Success response
JSON format
{
"RequestId": "C44F62BE-9CE7-4277-B117-69243F3988BF\n"
}
Error codes
|
HTTP status code |
Error code |
Error message |
Description |
|---|---|---|---|
| 400 | IllegalParam.JobId | The specified parameter JobId is illegal. | The entered failover test job ID is invalid. |
| 400 | IncorrectStatus.OnlyForInit | Only the init status failover test job can be started. | Only the fault drill task to be drilled can be modified or started. |
| 400 | EcFailoverTestJobResourceInAnotherProcessingJob | There is another processing failover test job. | The current user already has a failover test job in progress. Please complete it and try again. |
| 400 | IllegalParam.ResourceId | The input parameter resource ID is invalid. | The input parameter resource ID is invalid. |
| 400 | IncorrectStatus.ResourceId | The specified resource status is invalid. | The resource status corresponding to the entered resource ID is invalid. |
| 400 | IncorrectBusinessStatus.ResourceId | The specified resource business status is invalid. | The entered resource is in arrears. |
| 400 | VpconnNotAssociatedVbr | The specified vpconn is not associated with vbr. | The entered virtual physical connection is not associated with a virtual border router. |
| 400 | VpconnWithVlan0NotSupportShutdown | The specified virtualPhysicalConnection with vlan 0 does not support shutdown. | The shared physical connection of VLAN 0 does not support failover test. |
| 400 | PconnContainsMoreThanOneVpconn | The specified physicalConnection contains more than one virtualPhysicalConnection. | A physical line that contains more than one shared physical line does not support failover test. |
| 400 | PconnContailsMoreThanOneAcrossCountVbr | The specified physicalConnection contains more than one virtualBorderRouter which is across count. | Physical connections that contain more than one cross-account VBR do not support failover test. |
| 400 | EcFailoverTestJobConflict | The current failover test job task is in operation, please try again later. | The current failover test job task is in operation, please try again later. |
| 400 | AnotherJobTesting | There is another job which is testing. | The same user can only perform one fault drill task in the same region at the same time. |
See Error Codes for a complete list.