Method for testing the network performance of the leased line

Last Updated: Jan 09, 2018

After completing the leased line access, you need to test the performance of the leased line to ensure that it can meet your service needs.

Prerequisites

Before the test, ensure you have made the following preparations:

  • Complete configurations regarding leased line access and routes. The on-premises IDC must be connected to the VPC through a leased line.

  • Prepare a network access device for the on-premises IDC: The network access device is subjected to stress testing to test the packets per second (pps) of the on-premises IDC. It serves as the client or server in the netperf or iperf3 test.

    In this tutorial, the IP address of the on-premises IDC is 192.168.100.1.

  • Prepare eight VPC ECS instances: The ECS instances serve as clients or servers in the netperf or iperf3 test. They are connected to the network access device of the on-premises IDC to transmit test configurations and test results.

    In this tutorial, eight ECS instances are used, of which the specification is ecs.se1.2xlarge, the image is centos_7_2_64_40G_base_20170222.vhd, and the IP address range is 172.16.0.2 − 172.16.0.9.

Build the test environment

Install netperf

Netperf is a tool for testing network performance and is based on TCP or UDP transmission.

Follow these steps to install netperf on the network access device of the on-premises IDC and the eight ECS instances.

  1. Run the following command to download netperf:

    1. wget -c "https://codeload.github.com/HewlettPackard/netperf/tar.gz/netperf-2.5.0" -O netperf-2.5.0.tar.gz
  2. Run the following command to install netperf:

    1. tar -zxvf netperf-2.5.0.tar.gz
    2. cd netperf-netperf-2.5.0
    3. ./configure && make && make install && cd ..
  3. Run the netperf -h and netserver -h commands to verify if the installation is successful.

Install iperf3

Iperf3 is a tool for testing network performance and can test the maximum TCP or UDP bandwidth.

Follow these steps to install iperf3 on the network access device of the on-premises IDC and the eight ECS instances.

  1. Run the following command to download iperf3:

    1. yum install git -y
    2. git clone https://github.com/esnet/iperf
  2. Run the following command to install iperf3:

    1. cd iperf
    2. ./configure && make && make install && cd ..
    3. cd src
    4. ADD_PATH="$(pwd)"
    5. PATH="${ADD_PATH}:${PATH}"
    6. export PATH
  3. Run the iperf3 -h command to verify if the installation is successful.

Enable the multiple queue feature

Run the following command on the network access device of the on-premises IDC to enable the multiple queue feature (assume the interface connected to the leased line is eth0):

  1. ethtool -L eth0 combined 4
  2. echo "ff" > /sys/class/net/eth0/queues/rx-0/rps_cpus
  3. echo "ff" > /sys/class/net/eth0/queues/rx-1/rps_cpus
  4. echo "ff" > /sys/class/net/eth0/queues/rx-2/rps_cpus
  5. echo "ff" > /sys/class/net/eth0/queues/rx-3/rps_cpus

Use netperf to test the packet forwarding performance of the leased line

After being installed, netperf creates two command line tools: netserver (server side) and netperf (client side). Main parameters of the two tools are shown in the following table.

Tool name Main parameter Parameter description
netserver (server side: receiving side tool) -p The port of the server.
netperf -H The IP address of the network access device of on-premises IDC or the VPC server.
-p The port of the network access device of the on-premises IDC or the VPC server.
-l The duration of running.
-t The protocol used for sending packets: TCP_STREAM or UDP_STREAM.

We recommend UDP_STREAM.

-m The data packet size.
  • We recommend that you set the value to 1 when testing pps.
  • We recommend that you set the value to 1400 when testing bps (bit per second).

Test the inbound direction

  1. Start the netserver process on the network access device of the on-premises IDC and specify different ports:

    1. netserver -p 11256
    2. netserver -p 11257
    3. netserver -p 11258
    4. netserver -p 11259
    5. netserver -p 11260
    6. netserver -p 11261
    7. netserver -p 11262
    8. netserver -p 11263
  2. Start the netperf process on the eight ECS instances in the VPC and specify different ports connecting to the network access device of the on-premises IDC.

    1. netperf -H 192.168.100.1 -p 11256 -t UDP_STREAM -l 300 -- -m 1 #first ECS instance
    2. netperf -H 192.168.100.1 -p 11257 -t UDP_STREAM -l 300 -- -m 1 #second ECS instance
    3. netperf -H 192.168.100.1 -p 11258 -t UDP_STREAM -l 300 -- -m 1 #third ECS instance
    4. netperf -H 192.168.100.1 -p 11259 -t UDP_STREAM -l 300 -- -m 1 #fourth ECS instance
    5. netperf -H 192.168.100.1 -p 11260 -t UDP_STREAM -l 300 -- -m 1 #fifth ECS instance
    6. netperf -H 192.168.100.1 -p 11261 -t UDP_STREAM -l 300 -- -m 1 #sixth ECS instance
    7. netperf -H 192.168.100.1 -p 11262 -t UDP_STREAM -l 300 -- -m 1 #seventh ECS instance
    8. netperf -H 192.168.100.1 -p 11263 -t UDP_STREAM -l 300 -- -m 1 #eighth ECS instance
  3. If you want to test bps, change the preceding commands to:
    1. netperf -H 192.168.100.1 -p 11256 -t UDP_STREAM -l 300 -- -m 1400 #first ECS instance
    2. netperf -H 192.168.100.1 -p 11257 -t UDP_STREAM -l 300 -- -m 1400 #second ECS instance
    3. netperf -H 192.168.100.1 -p 11258 -t UDP_STREAM -l 300 -- -m 1400 #third ECS instance
    4. netperf -H 192.168.100.1 -p 11259 -t UDP_STREAM -l 300 -- -m 1400 #fourth ECS instance
    5. netperf -H 192.168.100.1 -p 11260 -t UDP_STREAM -l 300 -- -m 1400 #fifth ECS instance
    6. netperf -H 192.168.100.1 -p 11261 -t UDP_STREAM -l 300 -- -m 1400 #sixth ECS instance
    7. netperf -H 192.168.100.1 -p 11262 -t UDP_STREAM -l 300 -- -m 1400 #seventh ECS instance
    8. netperf -H 192.168.100.1 -p 11263 -t UDP_STREAM -l 300 -- -m 1400 #eighth ECS instance

Test the outbound direction

  1. Start the netserver process on the eight ECS instances in the VPC and specify the port as follows:

    1. netserver -p 11256
  2. Start eight netperf processes on the network access device of the on-premises IDC and specify different IP addresses.

    1. netperf -H 172.16.0.2 -p 11256 -t UDP_STREAM -l 300 -- -m 1 #first ECS instance
    2. netperf -H 172.16.0.3 -p 11256 -t UDP_STREAM -l 300 -- -m 1 #second ECS instance
    3. netperf -H 172.16.0.4 -p 11256 -t UDP_STREAM -l 300 -- -m 1 #third ECS instance
    4. netperf -H 172.16.0.5 -p 11256 -t UDP_STREAM -l 300 -- -m 1 #fourth ECS instance
    5. netperf -H 172.16.0.6 -p 11256 -t UDP_STREAM -l 300 -- -m 1 #fifth ECS instance
    6. netperf -H 172.16.0.7 -p 11256 -t UDP_STREAM -l 300 -- -m 1 #sixth ECS instance
    7. netperf -H 172.16.0.8 -p 11256 -t UDP_STREAM -l 300 -- -m 1 #seventh ECS instance
    8. netperf -H 172.16.0.9 -p 11256 -t UDP_STREAM -l 300 -- -m 1 #eighth ECS instance
  3. If you want to test bps, change the preceding commands to:
    1. netperf -H 192.168.100.1 -p 11256 -t UDP_STREAM -l 300 -- -m 1400 #first ECS instance
    2. netperf -H 192.168.100.1 -p 11257 -t UDP_STREAM -l 300 -- -m 1400 #second ECS instance
    3. netperf -H 192.168.100.1 -p 11258 -t UDP_STREAM -l 300 -- -m 1400 #third ECS instance
    4. netperf -H 192.168.100.1 -p 11259 -t UDP_STREAM -l 300 -- -m 1400 #fourth ECS instance
    5. netperf -H 192.168.100.1 -p 11260 -t UDP_STREAM -l 300 -- -m 1400 #fifth ECS instance
    6. netperf -H 192.168.100.1 -p 11261 -t UDP_STREAM -l 300 -- -m 1400 #sixth ECS instance
    7. netperf -H 192.168.100.1 -p 11262 -t UDP_STREAM -l 300 -- -m 1400 #seventh ECS instance
    8. netperf -H 192.168.100.1 -p 11263 -t UDP_STREAM -l 300 -- -m 1400 #eighth ECS instance

Analyze test results

The following results are displayed when netperf processes on the client side are completed.

  1. Socket Message Elapsed Messages
  2. Size Size Time Okay Errors Throughput
  3. bytes bytes secs # # 10^6bits/sec
  4. 124928 1 10.00 4532554 0 3.63
  5. 212992 10.00 1099999 0.88

Descriptions of fields in the test results are shown in the following table:

Field Description
Socket Size Buffer size
Message Size Packet size (Byte)
Elapsed Time The duration of test (s)
Message Okay The number of packets successfully sent out
Message Errors The number of packets fail to be sent out
Throughput Network throughput (Mbit/s)

You can obtain the pps of the tested link if you divide the number of packets successfully sent out by the duration of test. That is, pps = the number of packets successfully sent out / the duration of test

Use iperf3 to test the bandwidth of the leased line

Main parameters of iperf3 are shown in the following table.

Tool name Main parameter Description
iperf3 -s Indicates receiving packets as the server.
-i Interval between every two reports, in seconds.
-p The listening port of the server.
-u Indicates using the UDP protocol to send packets. If this parameter is not specified, the TCP protocol is used.
-l Indicates the length of the read-write buffer. We recommend that you set the value to 16 when testing the packet forwarding performance and to 1400 when testing the bandwidth.
-b The bandwidth used by the UDP mode, in bits/s.
-t Set the duration of transmission. In the specified time period, iperf repeatedly sends packets of specified length. The default value is 10 seconds.
-A CPU affinity. You can bind an iperf3 process to the logic CPU of the corresponding number to avoid cross-CPU scheduling of the iperf3 process.

Test the inbound direction

  1. Start the iperf3 process in the server mode on the network access device of the on-premises IDC and specify different ports as follows:
  1. iperf3 -s -i 1 -p 16001
  2. iperf3 -s -i 1 -p 16002
  3. iperf3 -s -i 1 -p 16003
  4. iperf3 -s -i 1 -p 16004
  5. iperf3 -s -i 1 -p 16005
  6. iperf3 -s -i 1 -p 16006
  7. iperf3 -s -i 1 -p 16007
  8. iperf3 -s -i 1 -p 16008
  1. Start the iperf3 process in the client mode on the eight ECS instances in the VPC and specify different ports connecting to the network access device of the on-premises IDC.
  1. iperf3 -u -l 16 -b 100m -t 120 -c 192.168.100.1 -i 1 -p 16001 -A 1
  2. iperf3 -u -l 16 -b 100m -t 120 -c 192.168.100.1 -i 1 -p 16002 -A 2
  3. iperf3 -u -l 16 -b 100m -t 120 -c 192.168.100.1 -i 1 -p 16003 -A 3
  4. iperf3 -u -l 16 -b 100m -t 120 -c 192.168.100.1 -i 1 -p 16004 -A 4
  5. iperf3 -u -l 16 -b 100m -t 120 -c 192.168.100.1 -i 1 -p 16005 -A 5
  6. iperf3 -u -l 16 -b 100m -t 120 -c 192.168.100.1 -i 1 -p 16006 -A 6
  7. iperf3 -u -l 16 -b 100m -t 120 -c 192.168.100.1 -i 1 -p 16007 -A 7
  8. iperf3 -u -l 16 -b 100m -t 120 -c 192.168.100.1 -i 1 -p 16008 -A 8

Test the outbound direction

  1. Start the iperf3 process in the server mode on each ECS instance in the VPC and specify the port:

    1. iperf3 -s -i 1 -p 16001
  2. Start eight iperf3 processes in the client mode on the network access device of the on-premises IDC and the value of -cis the IP address of each ECS instance.

    1. iperf3 -u -l 16 -b 100m -t 120 -c 172.16.0.2 -i 1 -p 16001 -A 1
    2. iperf3 -u -l 16 -b 100m -t 120 -c 172.16.0.3 -i 1 -p 16001 -A 2
    3. iperf3 -u -l 16 -b 100m -t 120 -c 172.16.0.4 -i 1 -p 16001 -A 3
    4. iperf3 -u -l 16 -b 100m -t 120 -c 172.16.0.5 -i 1 -p 16001 -A 4
    5. iperf3 -u -l 16 -b 100m -t 120 -c 172.16.0.6 -i 1 -p 16001 -A 5
    6. iperf3 -u -l 16 -b 100m -t 120 -c 172.16.0.7 -i 1 -p 16001 -A 6
    7. iperf3 -u -l 16 -b 100m -t 120 -c 172.16.0.8 -i 1 -p 16001 -A 7
    8. iperf3 -u -l 16 -b 100m -t 120 -c 172.16.0.9 -i 1 -p 16001 -A 8

Analyze test results

The following results are displayed when iperf3 processes on the client side are completed.

  1. [ ID] Interval Transfer Bandwidth Jitter Lost/Total Datagrams
  2. [ 4] 0.00-10.00 sec 237 MBytes 199 Mbits/sec 0.027 ms 500/30352 (1.6%)
  3. [ 4] Sent 30352 datagrams

Descriptions of fields in the rest results are shown in the following table:

Field Description
Transfer The total number of data transmitted
Bandwidth Bandwidth
Jitter Jitter
Lost/Total Datagrams The number of dropped packets / The total number of packets (packet loss)

PPS = The number of packets received by the peer end/Duration

Note: We recommend that you run the sar command on the server side to count the packets actually received and use the obtained value as the actual result, such as sar -n DEV 1 320.

Alibaba side speed limit

In addition to limits on the leased line, the following are limits on the communication between the VPC and the on-premises IDC:

  • The maximum read-write speed of OSS is 5 Gbit/s.

  • To improve the reliability, the speed of a single hash stream from the VPC to the VBR is limited to “Express Connect bandwidth / 12”. For example, if the bandwidth from the VBR to the VPC is large1, namely 1 Gbps, the maximum bandwidth of a single hash stream is 83 Mbps.

    Hash stream: The data stream that is defined by the combination of the source IP address, source port, transport layer protocol, destination IP address, and destination port. For example, “192.168.1.1 10000 TCP 121.14.88.76 80” forms a hash stream. A terminal whose IP address is 192.168.1.1 is connected to port 80 of a terminal whose IP address is 121.14.88.76 through port 10000 by using the TCP protocol.